zsom:getting_started

Quick start guide

This document describes how to begin using the ZSOM-Control ant ZSOM-Mini.

Before using the ZSOM, you must install the following application software and device drivers on the host computer.

Software
LabVIEW 2017 SP1 or later (See also thecompatibility information from NI )
LabVIEW Real-Time Module 2017 or later
LabVIEW FPGA Module 2017 or later 1)
NI CompactRIO Device Drivers 17.6 .. current (see copatibility chart to check which version of CompactRIO device drivers works on your LabVIEW version
ZSOM SDK see downloads (login required) see also upgrade SDK

:!: caution the heat spread can get hot :!:

Connect the ZSOM Plug with the delivered power supply. The Input voltage rating is 9-28 VDC, 1 A max.

The Status LED stays solid during boot and will turn off after boot

USB C

  1. Connect the "USB C" with the cable2) contained in the starter kit
  2. Device drivers are installed automatically

Windows7 success message

Ethernet

If you prefer connecting the device to your Network, use the RJ45 "ETH" connector.

The ZSOM-Control-Starterkit ships with installed Software and is ready to go. It si most likely, that your Installation does not match the software versions on the taregt. In that case, (Labview tells you when you want to deploy an application) use NI-MAX to install the maching software packages on the Target. If you want to deploy or retrieve your own image refer to Installing Software on ZSOM

The ecamples are installed with the SDK and can be foud via NI Example finder

The FPGA bitfiles are precompiled and enable for use without LabVIEW FPGA. The examples are built for a generic use of the board. They can be used as starting point for a customized application.

  1. Set IP to discovered address (ZSOM connected through USB C will have the IP “172.22.11.2”)
    1. Right-click on Realtime Target → Properties
  2. Connect
    1. Right-click on Realtime Target → Connenct
  3. Realtime Target icon on project explorer shows a light green dot on success

Open the “RT” Folder and the vi “RT_main.vi” and run it.


1)
is only required when using custom FPGA design
2)
must be USB3.0 capable
  • Last modified: 3 years ago