This is an old revision of the document!
On the ZMC hardware the ADC chip can be used in 2 different ranges: -5..+5V an -10..+10V. Default setting is -5V..+5V.
Currently there is no VI to change the range.
As a workaround you can:
A) use a voltage divider to get bigger ranges.
(Please keep in mind the adc input leakage current of app. 1uA)
B) you can use one of the following c-nodes to set the range pin of the ADC chip:
(Only functional when compiled and running in realtime on the target. The range won't be changed while working in FDM mode)
drag and drop this VI snippet into a LabVIEW block diagram.